Description
[pdf] [/pdf]
Temperature Measurement
| Parameter | Range | Resolution | Accuracy |
| Flue temperature | 32 to 1112F | 0.1F | (0.3% rdg +3.6F (2C)) |
| Inlet temperature (internal sensor) | 32 to 1112F | 0.1F | +1.8C +0.3% rdg |
| Inlet temperature (external sensor) | 32 to 1112F | 0.1F | +1.8C +0.3% rdg |
Flue Gas
| Parameter | Range | Resolution | Accuracy |
| Oxygen | 0 to 21% | 0.1% | +0.3% Volume |
| Carbon Monoxide | 0 to 2000ppm 2000 to 9999ppm Above 9999ppm |
1ppm | 3ppm or 5% of rdg 10% of rdg Unspecified |
| Carbon Dioxide | 0 to 20% | 0.1% | 0.3% rdg |
| Efficiency (Net or Gross) | 0 to 99.9% | 0.1% | +1.0% rdg |
| Efficiency High (C) | 0 to 119.9% | 0.1% | +1.0% rdg |
| Excess Air | 0 to 250% | 0.1% | +0.2% rdg |
| CO/CO2 ratio | 0 to 0.999% | 0.0001 | +5% rdg |
Pressure (Differential)
| Parameter | Range | Resolution | Accuracy |
| Pressure (Differential) | 80mbar | 0.1mbar | 0.5% FSD |
| Pre-programmed Fuels | NAT GAS, H OIL, PELLETS, OIL, LPG, BUTANE, PROPANE | – | – |
| User Programmed Fuels | 5 User-defined fuels | – | – |
| Storage Capacity | 45 Total Tests | – | – |
Advanced Combustion Analyzer For Commercial Boilers and Furnaces
Description
The UEi ACA is our first combustion analyzer, which is backed by UEi Service
The ACA features a new high-contrast graphic display, a new flue probe with integrated pressure readings, an H2 compensated 10,000 ppm CO sensor with purge pump protection, and wireless probe connection for use with optional wireless pipe clamp probes.
ACA allows techs to print to an optional printer through the IR port for hard copies or wirelessly to a compatible device using the KANE LIVE App to record and email results.
Features
Ambient CO2 readings to test building IAQ
Integrate optional wireless probes
CO over-range pump protection from high CO levels
High-contrast graphic display
UEi LOCK Theft Protection: Coming Soon (details below)
UEi Concierge+ 15-min analyzer review with a tech
CO sensor, 10,000ppm H2 Compensated & NOx filtered
CO2 sensor (flue or ambient)
O2, sensor
Differential Pressure and draft
Flue and Inlet Temperature, differential temperature
Combustion Efficiency and Excess Air
Heat Exchanger test
Room CO test
Optional NO (Nitric Oxide) sensor upgradable
Protective Boot with built-in magnetic mount
Low Flow Detection to protect reading accuracy
Flue probe with integrated gas, temperature, and draft hoseconnections
Protective water trap
Calibration countdown reminders
Optional thermal printer for on-site hard copy printouts






Reviews