Description
[pdf] [/pdf]
10 AWG 7C Shielded Copper PE/PVC Insulation PVC Jacket Control Cable 600V
Applications:
The 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90C for normal operation in wet and dry locations, 130C for emergency overload, and 250C for short circuit conditions.
Control Cable 600 Volt Copper Conductors, Polyethylene Polyvinyl Chloride (PE/PVC) Insulation Shielded Polyvinyl Chloride(PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free.
Also Known AS:
10 AWG 7C Shielded Control Cable, 10 AWG 7C Instrumentation Cable, Multi-Core Shielded Control Cable, 10 AWG 7C Shielded, Multi-Conductor Cable, Control & Signal Cable, Screened Control Cable, Industrial Control Cable, 10 AWG 7C Automation Cable.
Standards:
ASTM B3 Standard Specification for Soft or Annealed Copper Wire
ASTM B8 Concentric-Lay-Stranded Copper Conductors
CSA CSA marking is available upon request
ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1
ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu/hr) and ICEA T-29-520 – (210,000 Btu/hr)
VW-1 (Vertical-Wire) Flame Test
Construction:
Conductor:
7 strands class B compressed bare copper per ASTM B3 and ASTM B8
Insulation:
Polyethylene (PE) 20 Mils thick and Polyvinyl Chloride (PVC) 10 Mils thick for all cable sizes
Filler:
Polypropylene filler on cables with 5 or less conductors
Binder:
Polyester flat thread binder tape applied for cables with more than 5 conductors
Shielding:
5 mils tape shield
Rip Chord:
Rip chord for ease of jacket removal
Overall Jacket:
Polyvinyl Chloride (PVC) Jacket
Specifications:
Size: 10 AWG
Number of Conductors: 7
Diameter OverConductor(inch): 0.111
InsulationThickness (Mil):30
Jacket Thickness (Mil): 60
Approx. OD (In): 0.632
Copper Weight (Lbs/1000’Ft): 227
Approx. Weight (Lbs/1000’Ft): 358
DC Resistance /1000ft: 1.040
AC Resistance @ 90C /1000ft: 1.300
Min Bending Radius (In): 2.5
Allowable Ampacity At 60C (Amp): 21
Allowable Ampacity At 75C (Amp): 24
Allowable Ampacity 90C (Amp): 28
|
Compatible with Manufacturer |
|
| Southwire | 622296 |






Reviews