Description
[pdf] [/pdf]
12 AWG 3C W/G + Drain Wire Tinned Copper Stranded TC-ER VFD Flexible Cable 600/1000V
Application:
Power supply cable for VFDs and motors, suitable for cable tray, conduit, raceways, (TC-ER) and machine tool wiringconforming to NFPA 79. Suitable for free air and direct burial. Its flexible design is ideal for use on operation processes inaccordance with NEC Articles 336, 501 and 502 including, but not limited to: fans, pumps, conveyors, compressors, elevators and lifts, extruders, crushers and presses, assembly lines, food and beverage, wind energy and data centers. Cableis rated for -40C Cold Bend and Impact. Multiple approvals for multiple applications. Machine Flex Type TC-ER Variable Frequency Drive Cable, 600 Volts or 1000 Volts, Tinned Copper Conductors,Cross-Linked Insulation Type RHH/RHW-2, Thermoplastic Elastomer Jacket, Rated 90C Dry or Wet, -40C Cold Impact,Identification Method 4. 1000 Volts Flexible Motor Supply. CSA CIC/TC FT4 Flame. Sunlight Resistance, Direct Burial, TCU, Silicone Free
Also Known As:
12 AWG Machine Flex TCU Cable, 12 AWG VFD Power Cable, 12 AWG Flexible VFD Cable 600 V/1000 V, TC-ER Rated Variable Frequency Drive Cable, RHH/RHW-2 Flexible Motor Supply Cable, Shielded XLPE Insulated Tinned Copper VFD Cable, Tray-Rated (UL 1277) Industrial VFD Cable, CSA CIC/TC FT4 Control and Power Cable, Flexible Motor Lead Cable (WTTC 1000 V), Direct Burial & Sunlight-Resistant VFD Cable.
Construction:
Conductor:Class K flexible stranded tinned annealed copper per ASTM B33, B172, and B174
Insulation: Cross-linked insulation (Type RHH/RHW-2 on 14 AWG and larger
Ground: One green ground with yellow stripe cross linked insulation (size equal to phase conductor)
Drain Wire: Tinned copper drain wire
Shielding: 100% coverage aluminum/Mylar/aluminum foil, overall 85% coverage tinned copper braid
Jacket: Black Thermoplastic Elastomer (TPE) jacket
Standards:
ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
ASTM B174 Standard Specification for Bunch-Stranded Copper
UL 44 Thermoset-Insulated Wires and Cables
UL 758 Standard for Appliance Wiring Material Style 20886
UL 1277 Type TC-ER Standard Power and Control Cables (1000V 14AWG and Larger)
UL 2277 Flexible Motor Supply & Type WTTC
CSA C22.2 No. 210 Appliance wiring material products I/II A/B (Sizes 16 – 8AWG)
CSA C22.2 No.230 Tray Cables – Rated TC
CSA C22.2 No. 239 Control and instrumentation cables
ICEA S-58-679 Control Cable Conductor Identification Method 4
ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
Specifications:
Size: 12 AWG
Number of Conductors: 3 + 1G + 1D
Number of Strands: 65
Diameter OverConductor(inch): 0.094
InsulationThickness (Mil): 45
Ground No. xAWG: 1 x 12
Drain Wire No. x AWG: 1 x 12
Dia. OverShield (inch): 0.511
JacketThickness (Mil): 62
Approx. OD (inch): 0.635
CopperWeight (lb/1000ft): 131
Approx. Weight (lb/1000ft): 269
Allowable Ampacity At 75C: 25 Amp
AllowableAmpacity At 90C: 30 Amp
|
Compatible with Manufacturer |
|
| Southwire | 585344 |
| Mueller | 9131204 |






Reviews
There are no reviews yet.