250 MCM 7 Stranded Bare Copper Conductor Soft Drawn Wire
Other Names For 250-7 stranded bare copper conductors:
250-7 stranded bare copper wire, 250-7 stranded bare electrical wire, 250-7 bare copper ground wire, 250-7 raw copper wire, 250-7 bare earth wire, 250-7 hard-drawn copper wire, 250-7 medium-hard copper wire, 250-7 soft annealed copper wire
About 250-7 Stranded Bare Copper Wire:
Stranded Bare Copper Wire (class A) is an electrical wire suitable for overhead transmission and distribution. Flexible stranded copper wire (classes B and C) is designed for uninsulated hook up, jumpers, and grounds in electrical construction. The wire is uncoated and unalloyed, which lets the customers enjoy the pure benefits of a copper conductor. Bare conductors of this electrical wire exhibit superior conductivity compared to insulated versions.
250-7 Stranded Bare Copper Wire Applications:
250-7 Stranded bare copper wire is used for heavy-duty applications, including:
- Industrial Grounding
- Substations for connecting transformers, circuit breakers, etc.
- Overhead Transmission
- Power Distribution
- Bus Bars and Panel Boards
- Large Machinery
- HVAC Systems
- Mining Applications
250-7 Stranded Bare Copper Wire Construction:
Conductor:
Stranded Bare Copper Wire has a stranded copper conductor per ASTM B-1, B-2 and B-8. The conductor is available in hard, medium-hard, and soft-drawn combination unilay temper. Some of the advantages of copper in cables include conductivity, tensile strength, and the properties of the tensile expansion.
Insulation:
Uninsulated
Jacket:
Unjacketed
Standards:
- ASTM B-1, B-2, B-3, B-8, B-787
- National Electric Code (NEC)
- CSA
- UL listed
250-7 Stranded Bare Copper Wire Specifications:
- Size: 250 MCM
- No. of Strand: 7
- Cable Type: Soft Drawn Bare
- Weight lb/1000FT: 774 Lbs
|
Compatible with Manufacturer |
|
| Service Wire Co : | BST19S4/0 |
| Omni Cable | Q125037 |
| Houston Wire & Cable | HW00025001 |
[/short]
APPLICATIONS:
Solid and stranded (classes AA and A) bare copper are suitable for overhead transmission and distribution applications.
Stranded conductor of greater flexibility (classes B and C) are suitable for uninsulated hook up, jumpers, and grounds in
electrical construction. Soft Drawn copper is unilay construction.
SPECIFICATIONS:
- B-1 Hard-Drawn Copper Wire.
- B-2 Medium-Hard Copper Wire.
- B-3 Soft or Annealed Copper Wire.
- B-8 Concentric-Lay-Stranded Hard, Medium-Hard or Soft Copper Conductor.
- B-33 Tinned Conductors
- B-787 19 Wire Combination Unilay-Stranded Soft copper wire.
CONSTRUCTION:
Bare copper, solid or stranded. Available in tempers hard, medium-hard, or soft. Stranded conductors are concentrically
stranded in hard and medium-hard tempers and are Combination Unilay stranded in the soft-drawn temper.