Description
10/2 Solid Type MC Lightweight Aluminum Interlocked Armor Armorlite Copper Conductor 600V
Application:
Branch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
Fished or embedded in plaster.
Concealed or exposed installations.
Environmental air-handling spaces per NEC 300.22 (C).
Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
Installation in cable tray and approved raceways.
Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) &645.5(D)(2).
Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.
Also Known As:
10/2 Solid Type MC Cable, 10/2 Solid Lightweight Aluminum Armor, 10/2 Solid Interlocked Armor Cable, Armorlite Copper Conductor, 600V Electrical Cable, 10/2 Solid Commercial Wiring, 10/2 Solid Industrial Cable, Copper Electrical Conductor.
Construction:
Armorlite Type MC Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90C dry available in sizes 14 AWG through 2 AWG, and a green insulated grounding conductor. The conductors are cabled together and a binder tape bearing the print legend is wrapped around the assembly. Aluminum interlocking armor is applied over the assembly.
Standards:
UL 83
UL 1569
UL 1685
UL Online Product Guide Info – Metal-Clad Cable (PJAZ)
Federal Specification A-A59544 (formerly J-C-30B)
FT4/IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame Test
NFPA 70 (National Electrical Code), Article 330
Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems
REACH/RoHS-2 (Chemical Limit) Compliant
Features:
Reduces installation costs up to 50% over pipe and wire.
Lightweight aluminum armor–as much as 45% lighter than steel MC Cable.
Better grounding performance than Type AC
Also available in barrels, boxes, or prefab assemblies
UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117,W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065,C-AJ-4066, F-C-3038.
Cable reverse wound on reel for ease of pulling and installation. When pulling from coils, pull from inside to ensure easeof installation.
Anti-short bushings are not required for use with MC cable per the NEC and UL
Specifications:
Size: 10 AWG
Ground Wire size:10 AWG
No of conductors: 2+1 G
Weight (LBS/1000′): 150 lbs
Overall Diameter (INCHES) : 0.542
Ampacity 60C (140F): 30 Amps
Ampacity 75C (167F): 35 Amps
Ampacity 90C (194F): 40 Amps
|
Compatible with Manufacturer |
|
| Southwire : | White : 55116701 |






Reviews