🚚 Free Shipping Worldwide on Orders Over $30    🔄 30-Day Easy Returns

1 AWG 3C Type MV -105 Copper 5/8kV NLEPR Insulation 133/100% IL AIA Yellow PVC Jacket

SKU: A16420857
Inventory: In Stock
Category:
Original price was: $31.00.Current price is: $18.60.

Description

[pdf] [/pdf]

1 AWG 3C Type MV -105 Copper 5/8kV NLEPR Insulation 133/100% IL AIA Yellow PVC Jacket

Application:

The 5/8KV 133%/100% insulation level cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays,direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at theconductor temperature not in excess of 105C for normal operation, 140C for emergency overload, and 250C for short circuitconditions. Rated at -35C for cold bend when UL listed. Rated at -40C for cold bend and cold impact and marked with”LTGG” when CSA listed or dual UL/CSA listed. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501and 502.Rated for 1000 lbs./FT maximum sidewall pressure.

Also Known As:

1 AWG 3C MV-105 copper cable, Three conductor 5/8kV cable, NLEPR insulation copper cable, AIA copper conductor cable, 1 AWG 3C Yellow PVC jacket cable, 5/8kV MV cable, 133/100% IL cable, MV-105 5/8kV power cable, PVC jacketed copper cable, 1 AWG 3C 5/8kV Industrial copper cable.

Standards:

ASTM B3 Soft or Annealed Copper Wire
ASTM B8 Concentric-Lay-Stranded Copper Conductors
ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
ASTM B496 Compact Round Concentric-lay-standard copper
UL 1072 Medium-Voltage Power Cables
UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
ICEA S-97-682 Standard for Shielded Utility Cable Rated for 5 – 46kV
AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification TestRequirements)
Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. 5323(j)and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661

Construction:

Conductor:Class B compressed stranded bare copper per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33optional)
Conductor Shield:
Semi-conducting cross-linked copolymer
Insulation:
115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level,
Insulation Shield:
Strippable semi-conducting cross-linked copolymer
Copper Tape Shield:
Helically wrapped 5 mil copper tape with 25% overlap
Grounding Conductor:
Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8 (Tinned Copperper ASTM B33 optional)
Filler:
Wax paper filler
Binder:
Polypropylene tape
Armor:
Aluminum Interlocked Armor (AIA)
Overall Jacket:
Polyvinyl Chloride (PVC)

Specifications:

Size: 1 AWG
Number of Conductor:3 + 1G
Number of Strands: 19
Diameter Over Conductor (inch): 0.322
Diameter Over Insulation (inch): 0.590
Diameter Over Insulation Shield (inch): 0.650
Ground No. x AWG: 1×4
Diameter Over Armor(inch): 1.775
Jacket Thickness (mil): 65
Approx. OD (In): 1.907
Copper Weight lb/1000ft: 1074
Approx. Weight (Lbs/1000’Ft): 2092
Min Bending Radius (In): 13.3
DC Resistance @ 25C /1000ft: 0.128
AC Resistance @ 90 /1000ft: 0.162
Inductive Reactance @60Hz/1000ft: 0.039
Allowable Ampacity In Duct 90/105C Amp : 155/165
Allowable Ampacity In Air 90/105C Amp: 160/180

Compatible with Manufacturer

Southwire 556613

Reviews

There are no reviews yet.

Be the first to review “1 AWG 3C Type MV -105 Copper 5/8kV NLEPR Insulation 133/100% IL AIA Yellow PVC Jacket”

Your email address will not be published. Required fields are marked *

Product zoom ×